An indoor range is a building full of interlocking systems, and each one affects the others: the trap determines where the exhaust goes, the baffles protect the lights and ducts, the target carriers keep shooters out of the dirtiest part of the room. This checklist runs through the systems the Department of Energy's range design criteria cover, with NIOSH's guidance where it adds something. It is a planning list, not a specification — and it deliberately recommends no products.

A caution on the source: DOE's Range Design Criteria (2012) were written for DOE's own facilities. They are a useful, public description of what a range involves, but your designer, local codes and insurer set the standard you build to.

Start with four questions

DOE frames indoor range design around who will shoot there, what kind of shooting they will do, how many firing points you need, and how many people will use the range. Calibers in particular drive the rest: trap design, steel thickness and ventilation all depend on the most powerful round you allow.

The checklist

Bullet trap and backstop

Must run the full width and height of the range. See bullet traps and backstops explained for the designs and their trade-offs.

Baffles, deflectors and shields

Protect lights, ventilation ducts, the ceiling and target carriers from the occasional stray round. DOE is clear that they are for errant shots, not repeated strikes.

Floors, walls and ceilings

Must be impenetrable to the rounds you allow. DOE also calls for floors with a nonporous finish that slope toward the target line, floor guards, and drains to an approved filtration system, so cleaning water carries lead somewhere it can be captured. Smooth, enclosed ceilings help the air move cleanly downrange.

Shooting booths

Bullet-resistant, set close behind the firing line, and built so they do not block airflow. DOE notes they are not used on rifle-only ranges.

Target carriers and retrieval

Motorised target carriers do more than save time: DOE notes they keep shooters out of the downrange area where lead concentrations are highest, and NIOSH recommends automatic target retrieval for the same reason.

Ventilation and filtration

The most important lead control indoors. A separate system, pushing air from behind the shooters to exhaust at the trap, under negative pressure, with HEPA filtration. See shooting range ventilation explained.

Lighting

DOE separates general range lighting, lighting at the firing line, and lighting on the targets, each dimmable, plus battery emergency lighting for the exits. Fixtures downrange need baffle protection.

Sound control

Covers noise carried through the air and through the structure. NIOSH's guidance includes double-stud walls with an air gap, foam-core metal doors, an entry passage with self-closing doors at both ends, and laminated bullet-resistant glass for observation windows. It is also blunt that no noise control removes the need for shooters and staff to wear hearing protection.

Control booth and communications

A control booth protects the range officer from noise and lead while giving a view of the line. The public address system has to be understood by shooters wearing double hearing protection.

Range control and safety devices

Warning lights, alarms on any doors that open downrange, and compliance with the fire and life-safety code (NFPA 101 is the one DOE names).

Plumbing and hygiene

Fresh water for handwashing and cleaning, and a filtration system for range-cleaning waste water. NIOSH also recommends showers and separate lockers for staff, so work clothes and street clothes are kept apart.

Cleaning equipment

HEPA vacuums rated for the job, and the protective equipment staff need to use them. NIOSH says dry sweeping should never be used in a firing range. See lead management at shooting ranges.

The rest of the line

Heating behind and above the firing positions, and gun racks behind them.